Definition of 0I14I

 

0I14I CANNOT ADD TEB OR TEBV--INSUFFICIENT TABLE SPACE
Cause: No room in tables to add TEB (tape error block) or TEBV (tape error block by volume)
for device specified in preceding ADD command.
System Action: If IPL is from the keyboard, the system waits for operator response.
Otherwise IPL is completed. but the system must be re-lPLed if the device is required.
Programmer Action: Reassemble the supervisor with more TEB table space. To do this,
increase the number in the TEB option of the FOPT macro.
Operator Action: Give DEL commands for devices to be deleted before giving ADD com-
mands. If the problem recurs, execute a stand-alone dump (see DOS/VS SADP) and have the
· listing
· supervisor listing
· console log or IPL deck
available for problem determination.





Used with Courtesy and Permission of International Business Machines, Inc.