Definition of 0I30I

 

0I30I DATE=../../..,CLOCK=../../..,ZONE=xxxx/../..
where xxxx is either EAST or WEST, and ../../.. is the date and time in decimal notation.
Cause: The system prints these values during the first IPL procedure after power-on if
time-of-day clock support is provided, so that the operator may check them.
System Action: The system issues the message 0I10A GIVE IPL COMMANDS and enters a
wait state. The information stays in the system until the next 'power off'. After that message
0I30I appears again.
Programmer Action: none.
Operator Action: If the values given in the message are satisfactory, type in a SET command
without parameters. If date or time-of-day are not satisfactory, give a SET command with
DATE and CLOCK parameters. If none of the values correspond to those required, give a
complete SET command. In either of the latter cases, press ENABL SET at the time specified
in the CLOCK parameter of the SET command.





Used with Courtesy and Permission of International Business Machines, Inc.