Definition of 0I34D

 

0I34D X'cuu' BURST MODE AND X'cuu' MICR CONFLICT
Cause: Burst mode devices and magnetic ink character readers or optical reader/sorters have
been specified on the same byte multiplexer channel.
System Action: The system waits for an operator response.
Programmer Action: Check the supervisor assembly listing and any ADD commands and
make sure no tape and/or DASD devices are specified on the same byte multiplexer channel
as MICR devices. If necessary reassemble the supervisor and alter the DVCGEN macros.
Operator Action: Enter a DEL command for one of the given devices and then reissue the
SET command. If using a card reader for IPL or if the problem recurs, execute a stand-alone
dump (see DOS/VS SADP) and have the
· output
· supervisor listing
· log sheet or IPL deck
available for problem determination.