Definition of 0P76I

 

0P76I [JOB or SUB] xxxxxxxx CANCELED DUE TO INVALID DASD ADDR
Note: If xxxxxxxx is JOB ACCT, it can be reinitiated only with IPL. The associated job can be
rerun.
Cause: DASD file protect limits exceeded, or
The problem program has requested a record that is not the next sequential record on a
system logical unit (SYSIN, SYSLNK, SYSPCH, and SYSLST), or
An I/O operation has been issued to a previously closed sequential disk file.
System Action: The job or subtask is canceled.
Programmer Action: For a DASD with file protection check that the file has been opened and
that the extents are correct for the range of seeks in the program.
For a failure to process sequential records on a system logical unit, check for errors in the
source coding. Make the necessary corrections and resubmit the job.
If LIOCSS is used, this range of seeks for input files is normally determined by the extents
from the VTOC label, as made in a previous output run. This range should have corresponding
extents, defined by EXTENT statements. since these determine the area from which DASD file
protection allows reading.
If the problem recurs, have the following available for problem determination:
· job stream including extent information ‘
· program listing
· log sheet
· stand-alone dump (see DOS/VS SADP to obtain a meaningful storage dump)
· printer output
Operator Action: none.





Used with Courtesy and Permission of International Business Machines, Inc.