VintageBigBlue.org

 

Message - 0R00I


Nov 28, 2018

 

0R00I RSTRT UNIT INVALID SYSxxx
Cause: The symbolic unit specified on // RSTRT card is not assigned to the proper device
type.
System Action: The job is canceled.
Programmer Action: Use the LISTIO output to verify that the symbolic unit was properly
assigned. Check the // RSTRT card for correct parameters. Make the necessary corrections
and resubmit the job.
If the problem recurs, obtain a system dump (see DOS/VS SADP) and have the
· output
· log sheet
· job stream
· LISTIO output
available for problem determination.
Operator Action: Issue the LISTIO command and check that SYSxxx is properly assigned. If
correction is necessary, rerun the job; otherwise return the LISTIO output to your programmer.





Used with Courtesy and Permission of International Business Machines, Inc.