VintageBigBlue.org

 

Message - 0R11I


Nov 28, 2018

 

0R11I INVALID BB FOR VERIFY SYSxxx
Cause: The cell (bin) number specified in the DASD operator verification table is invalid for the
device assigned to SYSxxx.
System Action: The job is canceled.
Programmer Action: Check the LISTIO output for the correct assignment. Examine the source
listing to check that the fifth operand of the CHKPT macro (d pointer) is desired. correct, and
not being altered during execution. Check the operator verification table to see that the entries
consist of two hex bytes for the symbolic unit and two hex bytes for the bin number (valid bin
numbers are 0 for 2311, 2314, 2319, 3330. 3333 and 3340, and 0-9 for 2321).
If the problem recurs, have the
· program listing
· log sheet
· printer output
available for problem determination.
Operator Action: Issue the LISTIO SYSxxx command and check that the assignment has
been made correctly. If correction is necessary. rerun the job. If correction is not necessary,
return the LISTIO output to your programmer.





Used with Courtesy and Permission of International Business Machines, Inc.


Contact Us
This Site's Privacy Policy
Google's privacy policies