0S11I [JOB or SUB] xxxxxxxx CANCELED DUE TO PROGRAM CHECK
Cause: This message is issued instead of 0S03I when a routine in the transient area is
canceled. This message is preceded by 0S08I.
System Action: The job is canceled.
Programmer Action: Execute the PDAID program, Fetch/Load trace (see DOS/VS SADP), to
determine the transient in error. Check for non-IBM or user—modified transients that may be in
error.
If the problem recurs, have the
· Fetch! Load trace output
· log sheet
· printer output
available for problem determination.
Manually store X'02' in byte X'69' of real storage. Rerun the job and execute a stand-alone
dump (see DOS/VS SADP) when a wait state occurs.
Operator Action: none.