VintageBigBlue.org

 

Message - 0T14E


Nov 28, 2018

 

0T14E CLOCK DAMAGE. ALL MODES QUIET
Cause: The time-of-day clock is damaged (hardware). Damage to the time-of-day clock
requires that error recording due to corrected hardware failures be disabled. The second part of
the message does not apply to models 115 and 125.
System Action: HIR and ECC are placed in the quiet mode and processing continues.
Programmer Action: none.
Operator Action: Remove all time-dependent jobs from the job stream and continue
processing. Do not reset HIR and ECC to recording mode.