1C10A PLEASE ASSIGN [SYSRDR, SYSIPT, SYSLNK]
Cause:
1. A statement or command was to be read from SYSRDR, which is not assigned, or
2. An INCLUDE linkage-editor control statement with no operand was found and SYSIPT is
not assigned,
3. A // OPTION CATAL or LINK was detected and SYSLNK is not assigned.
System Action: If SYSLOG is assigned to a keyboard, the system waits for an operator
response; otherwise. the invalid statement is ignored.
Programmer Action: none.
Operator Action: Assign [SYSRDR (if required*),SYSIPT,SYSLNK] and press END (in case of
SYSLNK resubmit the // OPTION card), or
Type CANCEL to cancel job, or
Type IGNORE or press END/ENTER to continue processing if the statement which caused the
message is not required.
If the problem recurs, issue a LISTIO command and have the
· output
· job stream
· log sheet
available for problem determination.
* If you do not require SYSRDR. you may enter any valid statement or command.