Definition of 1C32A

 

1C32A PROGRAM NOT FOUND
Cause: The phase name specified in the EXEC command is not in the core image library.
System Action: If SYSLOG is assigned to a keyboard, the system waits for an operator
response; otherwise. the job is canceled.
Programmer Action: If the phase name entered by the operator is correct, execute DSERV to
determine whether the program is in the core image library. If not, catalog the program or
check that the correct SYSRES pack has been mounted.
If the problem recurs, have the
· job stream
· System dump
· DSERV output
· log sheet
available for problem determination.
Operator Action: Correct phase name in EXEC command, or
Check that the correct SYSRES pack is mounted, or
Reply CANCEL to terminate the job. Execute DSERV for the core image library, obtain a
system dump, and return the output to your programmer, or
Press END/ENTER to continue processing the next job step, if your programmer does not
need any documentation.
Note: If a new SYSRES pack is mounted, perform IPL.





Used with Courtesy and Permission of International Business Machines, Inc.