Definition of 1C3nA-I

 

1C3nA/I PROGRAM NOT FOUND
1C31A/I PROGRAM NOT FOUND
1C32A/I PROGRAM NOT FOUND
1C33A/I PROGRAM NOT FOUND
1C34A/I PROGRAM NOT FOUND
1C35A/I PROGRAM NOT FOUND
1C36A/I PROGRAM NOT FOUND
1C37A/I PROGRAM NOT FOUND
1C38A/I PROGRAM NOT FOUND
1C39A/I PROGRAM NOT FOUND
n indicates the number of fields processed when the error was detected
Cause: The phase name specified in the // EXEC statement is not in the core image library.
1C33A is issued if the job control command LOG was given, 1C33I if NOLOG was given.
System Action: The system waits for an operator response (A), or the job is canceled (I).
Programmer Action: Check the phase name in the // EXEC statement. If it is correct, use a
DSERV output to check that the program is in the core image library. If it is not, catalog the
program or ensure that the correct SYSRES pack has been mounted.
If the problem recurs, have the
· job stream
· DSERV output
· system dump
· log sheet
available for problem determination.
Operator Action: Check that the correct SYSRES and SYSCLB packs are mounted or check
the name in the // EXEC statement. If correction is possible (see Note 2), reenter the //
EXEC statement, or
Reply CANCEL to cancel the job. then execute DSERV for the core image library and obtain a
system dump, or
Press END/ENTER to continue processing.
Note 1: If a new SYSRES pack is mounted, perform IPL.
Note 2: If the name in the // EXEC statement should be LNKEDT or ALTEDT, reenter the
statements, starting from // OPTION.