1Q90I/E INVALID * $$ RDR STMT (n)
n = number of the incorrect operand
Cause: The RDR card was wrongly specified (action indicator E), or
A RDR card was detected in card input, but the reader routine was not started for card reader
and diskette (action indicator I), or
A RDR card specified reading a data file from diskette but POWER was not generated for
reading from diskette (action indicator I), or
A RDR card was read from a diskette (action indicator I).
System Action: E: The system is waiting for a correct RDR card.
I: The routine is canceled.
Programmer Action: none.
Operator Action: E; If possible type in the correct RDR statement (see DOS/VS System
Control Statements, GC33—5373); POWER will then continue and check this new statement.
Otherwise the type CANCEL.
I: Restart the reader routine and specify a 3540 in your S (start) command.