VintageBigBlue.org

 

Message - 1R16I


Nov 28, 2018

 

1R16I NO AVAILABLE DTF
Cause: The RJE routine being started either does not have an RJE block name in the RJE
block name list or the RJE block was not link—edited with the POWER system.
System Action: The S command is ignored.
Programmer Action: none.
Operator Action: Check the S command (RJE option) for line address and device, then enter
and retype the command, if they were incorrectly specified. Otherwise the RJE block name list
(RJBLKLST) assembly and the link edit map of the POWER system should be checked for the
indicated RJE block. See Modifying the RJE Block Name List and RJE BLOCKS in DOS/VS
System Generation.