VintageBigBlue.org

 

Message - 1R28E


Nov 28, 2018

 

1R28E NO QFILE RECORD AVAILABLE RJE line address
Cause: The indicated RJE routine found no QFILE record for the current job entry. A system
overload condition exists.
System Action: The RJE routine is placed in the wait state until one of the action options is
selected, or the specified number of 28—second retries has been executed. After that, a
time-out condition occurs.
Programmer Action: none.
Operator Action: Reply with the P command to terminate the RJE routine until QFILE space
can be made available. Or start a local printer or punch writer routine to process job entries
completely. Then enter the G command to continue processing.