Definition of 1R29I

 

1R29I device type ROUTINE HAS BEEN TERMINATED RJE line address
Cause:
1. The central system operator has requested routine termination via the P command, or
2. The RJEND generation parameter specified EXIT and an RJEND work station command
was received, or
3. The routine has determined that irrecoverable error conditions prevent further routine
activity.
System Action: The specified RJE routine has completed routine termination which includes
releasing buffers assigned to the routine.
Programmer Action: none.
Operator Action: Start the routine again by means of the RJE option of the S command.
Note: This message is preceded by four lines of diagnostic printout generated by the BTAM
macro LERPRT starting with *** LINE ERROR TOTALS ***





Used with Courtesy and Permission of International Business Machines, Inc.