VintageBigBlue.org

 

Message - 1R56A


Nov 28, 2018

 

1R56A EOT NOT EXPECTED
Cause: An EOT signal (end-of-transmission) or intervention-required signal from the work
station reader was received before the end of the job entry in progress.
System Action: The work station state (active/inactive/processing etc.) is preserved. The RJE
routine is placed in the wait state until the work station reader is started, unless the specified
number of 28-second retries is executed first. After that, time-out condition occurs.
Programmer Action: none.
Operator Action: Restart the work station reader with more RJE input. If a time-out occurs,
the complete job entry must be retransmitted. Use the STATUS command to acknowledge
previous job entries.