1R64A INVALID RJE WORK STATION COMMAND. NO USER LOGGED ON
Cause: A work station command (indicated by the sequence field at the end of the message),
which can be received only when a user is logged on, was transmitted.
System Action: Input from the work station card reader is flushed. The work station state is
preserved. The RJE routine is placed in the wait state until the work station reader is activated,
or the specified number of 28-second retries is executed. After that, time-out condition occurs.
Programmer Action: none.
Operator Action: A valid LOGON command must be transmitted. The command that was
rejected should then be retransmitted, together with all input that followed it.