Definition of 1R70A

 

1R70A PRINT FORMS formsid NEEDED FOR JOB ENTRY name. CONTINUE COMMAND
REOUIRED
Cause: The formsid for the print output does not agree with the formsid used for the previous
print output at this work station.
System Action: The RJE routine will wait for the appropriate CONTINUE command option
before processing the job entry output. The RJE routine is placed in the wait state until a
CONTINUE command is received or the specified number of 28-second retries, specified in the
POWER generation parameter RETRY, has been executed. After that, a time-out condition
occurs.
Note: The RJSTART command resets the print and punch output formsid to the system
default (blanks). If a nonblankformsid has been specified in the * $$ PRT statement, the first
output processed after the RJSTART command will cause the above message to be issued.
Programmer Action: none.
Operator Action: Reply with a CONTINUE command. (Refer to DOS/VS Operating Procedures
for a description of this command.)





Used with Courtesy and Permission of International Business Machines, Inc.