VintageBigBlue.org

 

Message - 2155I


Nov 28, 2018

 

2155I ESID NUMBER DOES NOT POINT TO CSECT
content of statement in error
Cause: The ESID number does not belong to a defined control section.
System Action: The invalid statement is ignored and processing continues, unless ACTION
CANCEL was specified to cancel the job.
Programmer Action: Refer to card format 1, linkage editor input cards (DOS/VS System
Control Statements, under Linkage Editol and compare this with the output on SYSLST. Refer
to card format 2 for the REP card format. If the REP card is in error, correct the ESID field. If
any other card is in error, recompile and link-edit the job.
If the problem recurs, have the following available for problem determination:
· linkage editor map
· log sheet
· job control cards
· object modules
· source deck
· program listing
Operator Action: none.