2158I NO CSECT LENGTH SUPPLIED
content of statement in error
Cause: END statement does not contain the length of the control section.
System Action: The invalid statement is ignored and processing continues, unless ACTION
CANCEL was specified to cancel the job.
Programmer Action: Allow the job to execute. If execution fails, recompile and link-edit the
program. If execution is successful, ignore the message.
If recompilation and link-editing do not correct the problem, have the
· linkage editor map
· log sheet
· job control cards
· object modules
· source deck
· program listing
available for problem determination.
Operator Action: none.





Used with Courtesy and Permission of International Business Machines, Inc.