VintageBigBlue.org

 

Message - 3E10I


Nov 28, 2018

 

3E10I I/O ERROR ON RECORDER FILE AT cchhr
Cause: Either the SYSREC header record is invalid or an irrecoverable I/0 error occurred on
the recorder file while executing EREP, or the record read was not in the correct format.
System Action: The EREP program skips the record in error and continues processing the
SYSREC file. If the header record is invalid, EREP is canceled.
Programmer Action: none.
Operator Action: When EREP is completed, re-IPL and issue the SET command with
RF=CREATE. If this message recurs, the SYSREC file should be moved or the pack initialized
and the files rebuilt.