VintageBigBlue.org

 

Message - 3M93I


Nov 28, 2018

 

3M93I PAGEPOOL LT 16K — PHASE NOT LOADED IN SVA
Cause: The pagepool is too small for loading a phase into the SVA.
System Action: No phases will be loaded into the SVA.
Programmer Action: A minimum pagepool of 16K is required for using the SVA. If
necessary, reallocate your real partitions to provide sufficient space for the page
pool.
3UI0I STATEMENT OUT OF SEOUENCE
Cause: Control statement missing or out of sequence, or
Operand in ADD statement is not greater than or equal to the last operand in the preceding
REP or DEL statement, or
Operand in ADD statement is not greater than the operand in an immediately preceding ADD
statement, or
An ADD statement does not match a statement within the source library book, or
The operand of an ADD, DEL, or REP statement exceeds the last sequence number of the
book to be updated.
System Action: The message is issued to SYSLST only. The book is not updated, and the
remaining control cards are checked for validity only.
Programmer Action: Check the card sequence in the job stream and check the parameters in
the control cards. Correct the error and resubmit the job.
If the problem recurs, have the
· job stream
· printer output
available for problem determination.
Operator Action: none.





Used with Courtesy and Permission of International Business Machines, Inc.