4113D NO HDR1 LBL FOUND filename SYSxxx=cuu
Cause: Standard label input was specified, but no standard header label was found.
System Action: This message is always followed by the last tape record read. If SYSLOG is
assigned to a keyboard, the system waits for an operator response; otherwise, the job is
canceled.
Programmer Action: Check that the correct tape was submitted and that it was properly
positioned. Check the program that created the tape to ensure that standard labels were
specified. Make the necessary corrections and resubmit the job.
If the problem recurs, have the following available for problem determination:
· printout of the label portion of the tape
· job stream
· program listing
· log sheet
Operator Action: Type CANCEL or press END/ENTER to cancel the job, or
Type IGNORE to continue processing if you are sure that the label is not necessary.