Definition of 4B28I

 

4B28I P LOST DATA SYSnnn=cuu TI=xxxx DC=dddddddddd DECB=aaaaaa
Cause: Unit check (lost data).
Probably, the input message was larger than the input area or a DIAL command was issued to
a line that was already 'off—hook'.
System Action: Processing continues.
Programmer Action: none.
Operator Action: Check for the errors listed under Cause.
If the problem persists, have the
· ROD command output
· EREP output (see DOS/VS SADP)
· system log
available for problem determination.