Definition of 4n72I

 

4n72I MOD AND DTF INCOMPATIBLE
4172I MOD AND DTF INCOMPATIBLE
4272I MOD AND DTF INCOMPATIBLE
4372I MOD AND DTF INCOMPATIBLE
4472I MOD AND DTF INCOMPATIBLE
4572I MOD AND DTF INCOMPATIBLE
4672I MOD AND DTF INCOMPATIBLE
4772I MOD AND DTF INCOMPATIBLE
4872I MOD AND DTF INCOMPATIBLE
4972I MOD AND DTF INCOMPATIBLE
Cause: An ISAM module assembled with the CORDATA option cannot process any DTF table
assembled without the IOSIZE option, or
The IOSIZE specified in the DTF is not large enough to contain at least one prime data record.
The logical unit specified in the message refers to the cylinder index.
System Action: The job is canceled.
Programmer Action: Correct the IOSIZE parameter in the DTF or remove the CORDATA
option from the ISMOD. Reassemble the appropriate component and resubmit the job.
If the problem recurs, have the
· problem program
· ISMOD assembly
· system dump
· linkage editor map (if the module was auto-linked)
available for problem determination.
Operator Action: none.





Used with Courtesy and Permission of International Business Machines, Inc.