Definition of 8212I

 

8212I DATA CHECK IN LABEL
Cause: A data check occurred in the count field while reading a label.
This is probably a hardware error.
System Action: The job is canceled.
Programmer Action: If the problem persists, recreate the file on another disk pack or data
cell and reinitialize the subject volume.
Operator Action: Rerun the job.
If the problem persists, have the
· job stream
· system log
· printer output
· ROD command output
· EREP output (see DOS/VS SADP)
available for problem determination.