VintageBigBlue.org

 

Message - 8F17D


Nov 28, 2018

 

8F17D INVALID xV VOL.SER.NO.
where x = I, O or N.
Cause: Volume serial number for the indicated parameter in the utility modifier statement is
not six alphanumeric characters.
System Action: If the SYSLOG device has a keyboard, the system waits for an operator
response: otherwise, the job is canceled.
Programmer Action: none.
Operator Action: Supply a corrected modifier card and type RETRY or type CANCEL (or press
END/ENTER) to cancel the job.





Used with Courtesy and Permission of International Business Machines, Inc.