Definition of 8F18D


Cause: The input (or output) disk volume serial number, nnnnnn. does not agree with the
volume serial number given in the IV (or OV) parameter in the utility modifier card.
System Action: If the SYSLOG device has a keyboard, the system waits for an operator
response; otherwise the job is canceled.
Programmer Action: none.
Operator Action: Mount the pack with the volume serial number given in the modifier card
and type NEWPACK to continue processing, or
Change the utility modifier card (changing the relevant parameter, or, for an output volume,
omitting the OV parameter) and type NEWCARD to continue processing. or
Type CANCEL (or press END/ENTER) to cancel the job.

Used with Courtesy and Permission of International Business Machines, Inc.