IEAOPT00 Parameters that control resource management algorithms
(in the System Resource Manager.)
RFC CPU=0.1,IOC=0.1 00000010
RMC ERV=500 00000020
Parameter in IEASYSxx
OPT=xx
Notes
The OPT contains two categories of information:
1.
Resource factor cofficients: [RFC [CPU=x.x][,IOC=x.x]
2.
Resource manager constant: [RMC ERV=xxxxxx]
Syntax
Parameters
Keyword Meaning Value-Range Default-Value
CPU Specifies the weighting factor by which the recommendation of
the CPU load adjusting function is to be multiplied, when an
address space is evaluated for swapping. 0.0-9.9 0.1
IOC Specifies the weighting factor by which the recommendation of
the I/O load adjusting function is to be multiplied, when an
address space is evaluated for swapping. 0.0-9.9 0.1
ERV Specifies the "enqueue residence value." This is a
multiplication factor used to calculate the amount of task
execution time during which an address space should not be
swapped out. 0-999999 1