MVIKEY00 Parameters to control MSSC data and messages.


MSVCCAT=MSVCCAT,MSSCSAMP=03,MSFMSG=JOURNAL 00050003

Parameter in IEASYSxx

None

Notes



Syntax

* Use columns 1 - 71. Columns 72-80 are ignored.
* Avoid embedded blanks.
* Separate consecutive parameters by a comma.
* Do not divide a parameter between consecutive records.
* Indicate continuation by a comma followed by one or more blanks after the
last entry on a record.

Parameters
Parameter Meaning and Use Value-Range Default Value

MSFMSG=xx
MSFMSG=JOURNAL
MSFMSG=xx,JOURNAL
Specifies where the space manager messages regarding the
volume inventory stats are to be written. xx identifies
the route code of the alternate console where they will
be written. JOURNAL specifies that the journal data set
is to be used to record these messages. However, if the
journal data set fills up, subsequent messages are lost
unless they are also directed to a console. 01-16 JOURNAL

MSSCSAMP=xx
Specifies how often the MSSC will sample the load on each
of the staging drive groups. The MSSC determines the least
and most=used groups and passes this information to device
allocation so device allocation can best choose a 3330V unit
when it must mount a new MSS volume. 00-99 minutes 03

MSVCCAT=xxxxxxxx
Specifies the high qualifier name of the volume inventory
and volume control journal data sets. 1-8
alphameric
characte MSVICAT